500 Kva Pole Mounted Transformer

Primary Voltage: 6KV–35KV or others

Secondary Voltage: 120V–600V or others

Power Rating: 500 KVA

Connection Type: Dyn11/Yyno or others

Standards: ANSI/IEEE, CSA/CAN, DOE

Certificate: CE, UL, cUL, CSA, SGS

The 500 kVA Pole Mounted Transformer adopts a sealed oil-immersed distribution transformer design, and its performance complies with IEC international electrotechnical standards. The core adopts high-quality cold-rolled silicon steel sheets with a fully mitered joint and non-punched structure. The winding is made of high-quality oxygen-free copper. The oil tank adopts a corrugated sheet type or expansion type heat dissipation structure.

500 kVA Pole Mounted Transformer Product Structure

Cylindrical Oil Tank

Integrated cylindrical steel oil tank, full-weld sealing process, oil-resistant and anti-corrosion coating, preventing oil leakage and adapting to harsh outdoor environments.

Corrugated Radiator

External corrugated heat dissipation structure of the tank body, oil-immersed self-cooling heat dissipation, no need to install additional fans, with uniform and stable heat dissipation.

High- & Low-Voltage Porcelain Bushings

High-strength insulated ceramic bushings, rainproof, anti-pollution and voltage-resistant, with firm wiring, effectively preventing creepage and leakage.

500 kVA Pole Mounted Transformer Application

Pole-mounted transformers are designed to supply power to residential overhead distribution loads. They are also suitable for light commercial loads, industrial lighting, and various power applications.

500 KVA Pole Mounted Transformer Technical Parameters

Item Standard Value Notes
Rated Capacity 500 kVA Apparent power of the equipment
Phase / Frequency 3 Phase / 50 Hz / 60 Hz 60 Hz for Philippines, North America and Southeast Asia export
Rated Primary Voltage 11kV Off-load tap range: ±2×2.5%, 5 positions
Common Secondary Voltage 6.6kV / 3.3kV / 0.415kV 11kV/6.6kV is the most common distribution step-down ratio
Vector Group Yy0 / YNa0 Star neutral point must be independently grounded
Cooling Method ONAN (ONAF forced air cooling optional) Standard configuration for outdoor box-type substation and distribution room
Insulation Class Class A mineral oil insulation Winding temperature rise ≤65K, top oil temperature rise ≤60K
Short-Circuit Impedance (Uk) 4% Unified standard impedance for 500kVA medium capacity autotransformer
No-load Current ≤0.5% Standard limit for high-permeability cold-rolled grain-oriented silicon steel sheets
Operating Noise (at 1m) ≤56 dB Urban residential area distribution noise reduction standard
Operating Environment Altitude ≤1000m, -25°C to +40°C Enhanced insulation and heat dissipation available for altitude >1000m
Tank Protection Rating IP54 fully sealed corrugated oil tank Rainproof, dustproof, suitable for coastal salt fog conditions in Philippines

Advantages of CHBEB 500 kVA Pole Mounted Transformer

Through CHBEB’s optimized design, the transformer can realize multiple protection functions, including overheating protection, overvoltage protection, overcurrent protection, overload protection, undervoltage protection, phase loss protection, short-circuit protection, and three-phase imbalance protection, improving the safety and stability of equipment operation.