Dry Type Isolation Transformer

Primary Voltage: 480V

Secondary Voltage: 120V

Power Rating: customize

Connection Type: Dyn11 (Delta-Primary, Wye-Secondary with neutral), or other configurations

Transformer Type: Dry Type Transformer

Standards: ANSI/IEEE, CSA/CAN, DOE

Certificates: UL, cUL, CSA, SGS, CE

Dry Type Isolation Transformer Product Introduction

This transformer adopts air insulation and air cooling with oil-free design, completely eliminating fire risks and dielectric leakage hazards. Featuring flame retardant, explosion-proof performance and low operating loss, it is equipped with an intelligent temperature control system and can be directly installed at load centers, making it the optimal solution for modern urban power grids and industrial power distribution. CHBEB Group Co., Ltd. is a professional transformer manufacturer and high-quality producer of dry-type transformers. The rated parameters of dry-type isolation transformers are listed below:

Standard Tap Changer

±2×2.5% off-circuit voltage regulation
· 380V: For aging power grids in Africa
· 400V: For the Middle East and mainstream African markets
· 480V: For industrial power grids in the United States

Connection Group

Dyn11 or Dy1
· Dyn11: For Middle East and Africa (IEC system)
· Dy1: Compliant with ANSI phase standards for the US market

Frequency

50Hz or 60Hz
· 50Hz: Municipal power grids in the Middle East and Africa
· 60Hz: United States and overseas self-contained generator sets

Short-Circuit Impedance

4%, 5.75% or 6%
· 4%: Conventional power distribution for the Middle East and Africa
· 5.75%/6%: For the US and oilfield working conditions with high short-circuit risks

No-load Loss

≤480W (50Hz) or customized per DOE standards (60Hz)
· Original loss values apply to 50Hz models; loss values shall be recalculated and retested to meet DOE energy efficiency standards for US shipments

Load Loss

≤1700W (120℃, 50Hz) or corresponding values specified by DOE (60Hz)
· Original parameters apply to 50Hz models; load loss recalculated for 60Hz US orders

Power Frequency Withstand Voltage

3kV/1min, 4kV/1min or UL specified withstand voltage levels
· 3kV basic version: For general African projects
· 4kV: For high-standard clients in the Middle East
· UL exclusive withstand voltage: For US certified models

Insulation Class

Class F or Class H
· Class F: Conventional indoor environments
· Class H: Harsh high-temperature and dusty environments in the Middle East

Cooling Mode

AN/AF
· Dual modes of natural air cooling and forced air cooling, applicable to all markets

Dry Type Isolation Transformer Product Advantages

The iron core is processed with high-quality grain-oriented silicon steel, and the yoke end faces are coated with special resin adhesive, delivering low loss, low noise and stable performance.

The interlayer of low-voltage coils is wound with pre-impregnated DMD material and cured at high temperature, providing excellent insulation performance and high overall mechanical strength.

The high-voltage coil adopts a segmented multi-layer cylindrical structure with longitudinal air channels, manufactured via vacuum pressure casting. It boasts high mechanical strength, strong short-circuit resistance, low partial discharge, and superior resistance to moisture, dust and salt spray.

The overall structure is concise, reasonable and elegant, facilitating easy operation and maintenance.

Application Advantages

Single unit available with both CE and UL certifications, supporting barrier-free global sales. Our dry-type isolation transformers cover but are not limited to the following application scenarios: As common electrical equipment in industrial and civil power distribution systems, dry-type transformers have specific selection criteria due to their structural features and applicable environments. They are widely deployed in locations with strict fire and explosion protection requirements, including high-rise buildings, metro stations, hospitals, data centers and other indoor power distribution sites. With air or resin as insulation and cooling medium without oil filling, they gain wide recognition for outstanding safety and environmental performance.

Are you looking for a dry type isolation transformer solution suitable for your project? Contact us for professional advice.

Dry Type Isolation Transformer Electrical Parameters

Rated Capacity & Voltage Parameters

Parameter Item GB / IEC (Domestic, Middle East, Africa) North America UL (United States) Description
Rated Capacity 10~2500kVA 10~2500kVA Apparent power in kVA, single-phase / three-phase optional
Rated Voltage Combination Common ratings: 380V/380V, 400V/400V; equipped with ±2×2.5% off-circuit tap regulation Common ratings: 480V/480V, 480V/208V; tap positions customized on demand The primary and secondary sides of isolation transformers can adopt identical voltage to achieve electrical isolation
Connection Group Dyn11 (mainstream for three-phase); Ii0 for small-capacity single-phase models Dy1 (mainstream for three-phase) Dyn11 features stronger harmonic suppression, ideal for buildings and energy storage systems
Rated Frequency 50Hz (60Hz compatible) 60Hz Iron core redesign and no-load loss adjustment required for frequency changes
Rated Current Three-phase: I=S/(√3U); Single-phase: I=S/U Same formula Calculated directly based on capacity and voltage

Insulation & Withstand Voltage Parameters

Parameter Item GB / IEC North America UL Description
Insulation Class Class F (temperature rise limit: 100K), Class H (temperature rise limit: 125K) Class F / Class H, temperature rise tested per UL standards Class H is preferred for high-temperature environments in the Middle East
Power Frequency Withstand Voltage Low-voltage winding: 3kV/1min; high-voltage winding rated per voltage class Low-voltage winding ≥4kV/1min; high-voltage winding rated per UL classes Destructive test to verify main insulation strength
Induced Withstand Voltage 2×rated voltage; test frequency>100Hz, test time t=120×(50/f), minimum 15s Same principle, test voltage and duration comply with UL specifications Inspects interlayer and turn-to-turn winding insulation
Insulation Resistance Measured with 2500V megohmmeter; ≥1000MΩ at ambient temperature, absorption ratio ≥1.3 Same measurement logic with stricter acceptance thresholds Non-destructive test to judge insulation dampness
Partial Discharge Level Epoxy cast type ≤10pC ≤5pC for stringent projects High partial discharge standards apply to new energy and energy storage projects

Loss & Impedance Parameters

Parameter Item GB / IEC North America UL Description
No-load Loss Adopts high-grade grain-oriented silicon steel, complying with national energy efficiency limits; fixed values at 50Hz Must meet DOE energy efficiency certification, loss recalculated for 60Hz Loss generated by iron core during no-load operation
Load Loss Measured winding copper loss at reference temperature: 120℃ for Class F, 145℃ for Class H Tested at temperatures specified by DOE Heat loss of windings under rated load
Short-circuit Impedance 4% and 6% common for power distribution 5.75% and 7% common Higher impedance delivers stronger short-circuit resistance yet larger voltage drop
No-load Current 1%~3% of rated current under rated voltage Same range, subject to energy efficiency requirements Excitation current of iron core; lower value with higher-quality silicon steel

Temperature Rise, Cooling & Protection Parameters

Parameter Item Details
Cooling Mode AN Natural Air Cooling, AF Forced Air Cooling; fan activation boosts overload capacity by 30%~50%
Temperature Control System (Standard Pt100 temperature probes) Fan starts at 80℃; high-temperature alarm at 130℃; over-temperature trip at 150℃
Noise Level 50–60dB under rated operating conditions, suitable for indoor environments such as hospitals and office buildings
Short-circuit Withstand Capacity Tolerates 2-second internal and external short-circuit current impact without winding deformation

FAQ

What is the maximum capacity of dry-type transformers manufactured by CHBEB?

30kVA to 20MVA. Contact us for special customized requirements.

As a transformer manufacturer, what raw materials does CHBEB select?

We adopt different materials in accordance with capacity standards and customized client demands, including high-permeability low-loss cold-rolled grain-oriented silicon steel sheets, enameled wires with heat resistance up to 180℃, high-temperature resistant BT terminal blocks and insulation boards. Clients with strict quality requirements are welcome to consult us.